The charging station can be configured with contactless IC card swiping function, and charging can only be carried out through authorized IC card. If the IC card is lost, the internal dip switch can be used to set the IC card losing module. There are 2 IC cards which are authorized by the factory , unless specify that we can provide more IC cards.
This function is the automatic distribution of charging current, through an external current transformer (the output current is AC5A), the longest wiring length of the transformer is 100mm (2.5 square).
During the charging process, the charging station will monitor the online charging current in real time and make corresponding adjustments.
When it is detected that the current of the main circuit is greater than the set current, the charging station will reduce the charging current until the charging is stopped.
When it is detected that the current of the main circuit is less than the set current, the charging station will continue to increase the charging current until 32A or 63A.
In this state, the maximum charging current of the charging station is 32A and 63A.
While the charging current is uncertain, the current setting switch of the charging station becomes the transformation ratio setting switch of the current transformer. The transformation ratio of the external current transformer is set by software or factory setting. The factory default current transformer transformation ratio is 100A/5A.